FOTRIC H6 High-Performance Acoustic Camera
Introducing the FOTRIC H6 High-Performance Acoustic Imaging Camera, our latest innovation in industrial inspection. This cutting-edge tool combines leak evaluation and partial discharge detection into one powerful device. Equipped with up to 162 MEMS digital microphones, the H6 offers unparalleled sensitivity to detect even the faintest acoustic signals. Its Acoustic Focus Mode ensures precise targeting and accurate diagnostics, making it essential for maintaining equipment integrity and preventing costly failures. Elevate your inspection capabilities with the H6, where exceptional performance meets advanced technology.
Main Specifications
Product Catalog & Full Specifications
Analysis Software
Model | FOTRIC H6 |
---|---|
Microphone channels | 162 MEMS digital microphones |
Acoustic Image FOV |
66° × 52° |
Acoustic Sampling Rate |
200kHz |
Acoustic Refresh Rate |
25Hz |
Working Distance |
0.3~200m(1~626ft) |
Frequency Range |
2~100kHz |
Frequency Range Selection |
Support preset frequency range for different scenarios for later manual adjustment selection; Support for frequency range. |
Detection Mode |
LQ Mode: Displays the leakage PD level; PD Mode: Displays a PRPD diagram, adapted to different AC Default AC Frequency frequencies (50/60Hz). |
On-device Analysis |
The device can directly analyse acoustic images |
Analysis Software |
AnalyzIR professional thermal and acoustic image analysis software. |
Leak Evaluation |
Automatic identification of leakage points, automatic evaluation of leakage, and annual energy costs. |
Partial Discharge Diagnostics |
Automatic diagnosis of discharge types such as surface, floating, and Acoustic Imaging Display tip (corona) discharges. |
Display Screen |
5", 1280*720 pixels, LCD touchscreen display with Gorilla Anti-Explosion screen. |
LED Flash Lamp |
Supports torch illumination and flash light mode |
Battery Operation Time | 2 batteries, Continuous work ≥ 4h per battery (depends on the environment and workload) |
Enclosure Rating |
IP54(IEC 60529) |
Operating temperature | -4~112 ℉ (-20°C to 44.4°C) |
Storage temperature |
-40~158 ℉ (-40 to 70 ℃) without battery |
Operating Humidity | <95%RH |
Weight (include battery) |
2.86lb (1.3 kg) |
Warranty |
2 years |
Recommended Calibration Interval |
1 year |
*Some features might be added or slightly altered according to the region and country